MSCC7 Series
MSCC7 Series, Calibration Cart
MSCC7 Series

Calibration Cart, Dual Sensor


 

Dual Power Sensor Support


The MSCC7 Calibration Cart is a unique calibration solution in that it is designed to support two Power Sensors. In addition, it includes a user friendly 4421A Multifunction Power Meter and a high power load in an easily transportable mobile cart. The system is indispensable for semiconductor clean room applications.

The Calibration Cart is factory configured to the user’s requirements. A selection of Directional or Filtered Power Sensors are available covering various frequency bands from 100 kHz to 30 MHz. Load options include a number of high power loads available with a low reflection of 50 Ohm that can dissipate up to 10 kW max. Contact Bird for customization assistance to ensure that the calibration cart is optimized to your application.

PRODUCT FEATURES
  • Designed to support two power sensors
  • Suitable for use in a clean room environment
  • Stainless steel cart is designed for easy transportation and effortless use
  • Customizable with choice of power sensor and load configuration
  • High return loss ensures minimal power measurement error contribution
INCLUDES (See Product Selection Guide on the Datasheet for full details)
  • 4421A Series Multifunction Power Meter to display RF power readings with up to 1% accuracy
  • Two 4020, 4027A, or 4027F Power Sensors for accurate RF measurement
  • A High Power Load for precision RF power regulation and control
MSCC7 Series, Calibration Cart
MSCC7 Series
product specifications:
Item No
MSCC7 Series
Item Name
Dual Sensor Calibration Cart
Meter
4421A Multifunction Power Meter
Sensor Options
Two 4020, 4027A, or 4027F Series (See Datasheet)
Load Options
Bird High Power Load (See Datasheet)
Frequency Range
100 kHz to 30 MHz, depending on sensor
Accuracy
4020 Series Sensor
±3% across power and frequency range

4027A Series Sensor
±1% at calibration frequency and power levels
±2% over remainder of power range, and at other than calibration frequencies

4027F Series Sensor
±1% across power and frequency range
±2% over remainder of power range, and at other than calibration frequencies

Impedance Ω
50 Ohm, nominal
Power Requirements
115 or 230 VAC, 50/60 Hz
Connectors
Customer specified (See Datasheet)
Construction
Stainless steel cart with (4) locking swivel casters
Temperature
Operating: 0 to 35 °C (32 to 95 °F)
Storage: -20 to 70 °C (-4 to 158 °F)
Humidity
85% (max), non condensing
Altitude
Load derated above 5,000 ft (1,524 m)
Size
52 in x 20 in x 42 in (132 cm x 51 cm x 107 cm)
Weight
290 lb (132 kg)
Certifications
CE Compliant